58 research outputs found

    Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    Get PDF
    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P < 0.001), homogeneity of the luminal content (P < 0.001), delineation of the bowel-wall to the lumen (P < 0.001) and to the mesentery (P < 0.001) and artifacts (P < 0.001), leading to a significant better overall image quality (P < 0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P < 0.001) and wall to lumen delineation (P < 0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient populatio

    MR motility imaging in Crohn's disease improves lesion detection compared with standard MR imaging

    Get PDF
    Objective: To evaluate retrospectively in patients with Crohn's disease (CD) if magnetic resonance (MR) motility alterations correlate with CD typical lesions leading to an increased detection rate. Methods: Forty patients with histologically proven CD underwent MR enterography (MRE), including coronal cine sequences (cine MRE), in addition to the standard CD MR protocol. Two blinded readings were performed with and without cine MRE. Locations presenting motility alterations on the cine sequences were analysed on standard MRE for CD-related lesions. This was compared with a second reading using the standard clinical MRE protocol alone. Results: The number of lesions localised by cine MRE and identified on standard MRE compared with standard MRE alone were 35/24 for wall thickening (p = 0.002), 24/20 for stenoses (p = 0.05), 17/11 for wall layering (p = 0.02), 5/3 for mucosal ulcers (p = 0.02) and 21/17 for the comb sign (p = 0.05). Overall, cine MRE detected 35 more CD-specific findings than standard MRE alone (124/89; p = 0.007) and significantly more patients with CD-relevant MR findings (34/28; p = 0.03). Conclusion: CD lesions seem to be associated with motility changes and this leads to an increased lesion detection rate compared with standard-MRE imaging alon

    Gradient-enhanced volume rendering: an image processing strategy to facilitate whole small bowel imaging with MRI

    Get PDF
    MRI of the small bowel with positive contrast from orally administered contrast agent is a promising non-invasive imaging method. The aim of our study was to introduce small bowel MRI in a display format that clinicians are accustomed to and that maximizes the amount of information visualized on a single image. Twelve healthy volunteers, median age 32years (range 18-49 years) participated in the study. A mixture of 20ml Gd-DOTA (Dotarem), 0.8g/kg body weight psyllium fibre (Metamucil) and 1.2l water were sequentially administered over a period of 4h. Imaging was performed on a 1.5Tunit (Philips Gyroscan, Intera). Fat-saturated, 3D, gradient echo imaging was performed while the patient was in apnea (30s). Bowel motion was reduced with 40mg intravenously administered scopolamine (Buscopan). A 3D, gradient-enhanced, volume rendering technique was applied to the 3D data sets. Standard projections [left anterior oblique (LAO), right anterior oblique (RAO), supine and prone] resembling conventional enteroclysis were successfully generated within fewer than 10min processing time. Reconstructions were reproducible and provided an entire overview of the small bowel. In addition thin-slab volume rendering allowed an overlap-free display of individual structures. Positive contrast from orally administered contrast agent, combined with a gradient enhanced volume rendering method, allows the reconstruction of the small bowel in a pattern resembling conventional double-contrast enteroclysis. Segmental display without overlay is possibl

    Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers

    Get PDF
    Objective: To retrospectively analyze the performance of a commercial computer-aided diagnosis (CAD) software in the detection of pulmonary nodules in original and energy-subtracted (ES) chest radiographs. Methods: Original and ES chest radiographs of 58 patients with 105 pulmonary nodules measuring 5-30mm and images of 25 control subjects with no nodules were randomized. Five blinded readers evaluated firstly the original postero-anterior images alone and then together with the subtracted radiographs. In a second phase, original and ES images were analyzed by a commercial CAD program. CT was used as reference standard. CAD results were compared to the readers' findings. True-positive (TP) and false-positive (FP) findings with CAD on subtracted and non-subtracted images were compared. Results: Depending on the reader's experience, CAD detected between 11 and 21 nodules missed by readers. Human observers found three to 16 lesions missed by the CAD software. CAD used with ES images produced significantly fewer FPs than with non-subtracted images: 1.75 and 2.14 FPs per image, respectively (p = 0.029). The difference for the TP nodules was not significant (40 nodules on ES images and 34 lesions in non-subtracted radiographs, p = 0.142). Conclusion: CAD can improve lesion detection both on energy subtracted and non-subtracted chest images, especially for less experienced readers. The CAD program marked less FPs on energy-subtracted images than on original chest radiograph

    Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice

    Get PDF
    The purpose of this retrospective study was to evaluate the impact of energy subtraction (ES) chest radiography on the detection of pulmonary nodules and masses in daily routine. Seventy-seven patients and 25 healthy subjects were examined with a single exposure digital radiography system. Five blinded readers evaluated first the non-subtracted PA and lateral chest radiographs alone and then together with the subtracted PA soft tissue images. The size, location and number of lung nodules or masses were registered with the confidence level. CT was used as standard of reference. For the 200 total lesions, a sensitivity of 33.5-52.5% was found at non-subtracted and a sensitivity of 43.5-58.5% at energy-subtracted radiography, corresponding to a significant improvement in four of five readers (p < 0.05). However, in three of five readers the rate of false positives was higher with ES. With ES, sensitivity, but not the area under the alternative free-response receiver operating characteristics (AFROC) curve, showed a good correlation with reader experience (R = 0.90, p = 0.026). In four of five readers, the diagnostic confidence improved with ES (p = 0.0036). We conclude that single-exposure digital ES chest radiography improves detection of most pulmonary nodules and masses, but identification of nodules <1cm and false-positive findings remain a proble

    Aperistaltic effect of hyoscine N -butylbromide versus glucagon on the small bowel assessed by magnetic resonance imaging

    Get PDF
    The aim of this prospective study was to compare the intraindividual aperistaltic effect of 40mg hyoscine N-butylbromide (HBB/Buscopan) with that of 1mg glucagon on small bowel motility by using magnetic resonance imaging (MRI). Ten healthy volunteers underwent two separate 1.5-T MRI studies (HBB/glucagon) after a standardized oral preparation with an aqueous solution of Gd-DOTA and ispaghula (Metamucil). A 2D T1-w GRE sequence was acquired (TR 2.7ms/TE 1.3ms, temporal resolution 0.25s) before and after intravenous (i.v.) drug administration and motility was followed over 1h. On the resulting images the cross-sectional luminal diameters were assessed and plotted over time. Baseline motility frequency, onset of aperistalsis, duration of arrest, reappearance of motility and return to normal motility were analysed. Significant differences regarding reliability and duration of aperistalsis were observed. In the HBB group aperistalsis lasted a mean of 6.8 ± 5.3min compared with 18.3 ± 7min after glucagon (p < 0.0001). In 50% of cases HBB did not accomplish aperistalsis, whereas glucagon always succeeded (p = 0.05). There were no significant differences in terms of baseline and end frequencies for the onset of aperistalsis (22.2 ± 37.5s HBB/13.4 ± 9.2s glucagon, p = 0.1), nor for the return to normal motility. Arrest of small bowel motion is achieved more reliably and lasts significantly longer after i.v. administration of 1mg glucagon compared with 40mg HB

    Too Hard to Find with Too Little Time: What School Social Workers Want in Online Resources for Evidence-Based Practice

    Get PDF
    School mental health practitioners, including social workers, are mandated through federal, state, and professional entities to provide evidence-based practices to students. Nevertheless, rates of use of evidence-based practices among mental health professionals in schools remain low, even as knowledge about effective practices increases. This study aimed to further knowledge about how to promote and support the use of evidence-based practices among school practitioners using online technology. School social workers attending a summer professional development event took part in focus groups exploring (a) their current perceptions of evidence-based practices, (b) their experiences finding evidence-based practice information online, and (c) their preferences for the formatting and content of online resources. Participants described a willingness to use evidence-based practice, efforts to find information, and difficulties encountered with online sources. Preferences for readily available, searchable, brief, and understandable online information were expressed. Implications for meeting the needs of school social workers with online resources are discussed

    Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80kVp in 100 patients

    Get PDF
    The objective of this retrospective study was to assess image quality with pulmonary CT angiography (CTA) using 80kVp and to find anthropomorphic parameters other than body weight (BW) to serve as selection criteria for low-dose CTA. Attenuation in the pulmonary arteries, anteroposterior and lateral diameters, cross-sectional area and soft-tissue thickness of the chest were measured in 100 consecutive patients weighing less than 100kg with 80kVp pulmonary CTA. Body surface area (BSA) and contrast-to-noise ratios (CNR) were calculated. Three radiologists analyzed arterial enhancement, noise, and image quality. Image parameters between patients grouped by BW (group 1: 0-50kg; groups 2-6: 51-100kg, decadally increasing) were compared. CNR was higher in patients weighing less than 60kg than in the BW groups 71-99kg (P between 0.025 and <0.001). Subjective ranking of enhancement (P = 0.165-0.605), noise (P = 0.063), and image quality (P = 0.079) did not differ significantly across all patient groups. CNR correlated moderately strongly with weight (R = −0.585), BSA (R = −0.582), cross-sectional area (R = −0.544), and anteroposterior diameter of the chest (R = −0.457; P < 0.001 all parameters). We conclude that 80kVp pulmonary CTA permits diagnostic image quality in patients weighing up to 100kg. Body weight is a suitable criterion to select patients for low-dose pulmonary CT

    Magnetization transfer for the assessment of bowel fibrosis in patients with Crohn's disease: initial experience

    Get PDF
    Object: To assess the feasibility of magnetization transfer (MT) imaging of the bowel wall in patients with Crohn's disease (CD), and to evaluate its utility for the detection of intestinal fibrosis. Materials and methods: In this prospective study, 31 patients (age 39.0±13.2years) with CD were examined in a 1.5T MR scanner. To establish a standard of reference, two independent readers classified the patients in different disease states using standard MR enterography, available clinical data and histological findings. In addition to the standard protocol, a 2D gradient-echo sequence (TR/TE 32ms/2.17ms; flip angle 25°) with/without 1,100Hz off-resonance prepulse was applied. MT ratios (MTR) of the small bowel wall were computed off-line on a pixel-by-pixel basis. Results: The MT sequences acquired images of sufficient quality and spatial resolution for the evaluation of the small bowel wall without detrimental motion artefacts. In normal bowel wall segments, an intermediate MTR of 25.4±3.4% was measured. The MTR was significantly increased in bowel wall segments with fibrotic scarring (35.3±4.0%, p<0.0001). In segments with acute inflammation, the mean MTR was slightly smaller (22.9±2.2%). Conclusion: MT imaging of the small bowel wall is feasible in humans with sufficient image quality and may help with the identification of fibrotic scarring in patients with C

    MR motility imaging in Crohn's disease improves lesion detection compared with standard MR imaging

    Get PDF
    To evaluate retrospectively in patients with Crohn's disease (CD) if magnetic resonance (MR) motility alterations correlate with CD typical lesions leading to an increased detection rate
    • …
    corecore